Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42.742
Filtrar
1.
J Photochem Photobiol B ; 255: 112927, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38701631

RESUMEN

Since the mechanism underlying real-time acquisition of mechanical strength during laser-induced skin wound fusion remains unclear, and collagen is the primary constituent of skin tissue, this study investigates the structural and mechanical alterations in collagen at temperatures ranging from 40 °C to 60 °C using various spectroscopic techniques and molecular dynamics calculations. The COMSOL Multiphysics coupling is employed to simulate the three-dimensional temperature field, stress-strain relationship, and light intensity distribution in the laser thermal affected zone of skin wounds during dual-beam laser welding process. Raman spectroscopy, synchronous fluorescence spectroscopy and circular dichroism measurement results confirm that laser energy activates biological activity in residues, leading to a transformation in the originally fractured structure of collagen protein for enhanced mechanical strength. Molecular dynamics simulations reveal that stable hydrogen bonds form at amino acid residues within the central region of collagen protein when the overall temperature peak around the wound reaches 60 °C, thereby providing stability to previously fractured skin incisions and imparting instantaneous strength. However, under a 55 °C system, Type I collagen ensures macrostructural stability while activating biological properties at amino acid bases to promote wound healing function; this finding aligns with experimental analysis results. The COMSOL simulation outcomes also correspond well with macroscopic morphology after laser welding samples, confirming that by maintaining temperatures between 55 °C-60 °C during laser welding of skin incisions not only can certain instantaneous mechanical strength be achieved but irreversible thermal damage can also be effectively controlled. It is anticipated that these findings will provide valuable insights into understanding the healing mechanism for laser-welded skin wounds.


Asunto(s)
Colágeno , Rayos Láser , Simulación de Dinámica Molecular , Piel , Espectrometría Raman , Piel/química , Piel/efectos de la radiación , Colágeno/química , Colágeno/metabolismo , Cicatrización de Heridas , Enlace de Hidrógeno , Análisis de Elementos Finitos , Animales , Dicroismo Circular , Temperatura , Espectrometría de Fluorescencia
2.
J Dig Dis ; 25(3): 191-199, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38697920

RESUMEN

OBJECTIVE: To compare the detection rate and diagnostic accuracy of cardia polyps using endoscopy with blue laser imaging (BLI) and white-light imaging (WLI). METHODS: Patients were randomly divided into the BLI group and WLI group according to the endoscopic procedures. BLI followed by WLI was conducted in the BLI group, whereas WLI followed by BLI examination was conducted in the WLI group. The number, size, microstructure, and microvascular patterns of cardia polyps detected were recorded. Biopsy of the polyps was then performed. RESULTS: The detection rate of cardia polyps in the BLI group was higher than that in the WLI group (7.87% vs 4.22%, P = 0.018). The rate of overlooked lesions in the BLI group was lower than in the WLI group (0.64% vs 3.38%, P = 0.003). The diagnostic coincidence rate between magnifying BLI and histopathology was 88.16%. The sensitivity, specificity, positive predictive value and negative predictive value for the diagnosis of neoplastic lesions by magnifying endoscopy with BLI were 90.91%, 87.69%, 55.56%, and 98.28%, respectively. The most remarkable patterns for predicting inflammatory polyps were the prolonged and fine network patterns (sensitivity 71.43%, specificity 93.75%). Small round combined with honeycomb patterns were the most common among fundic gland polyps (sensitivity 80.00%, specificity 98.48%). Neoplastic lesions presented as villous or ridge-like combined with core vascular or unclear pattern for both microvascular and microstructure patterns. CONCLUSION: BLI is more effective than WLI in the detection and diagnosis of cardia polyps, and magnifying endoscopy with BLI may help diagnose such lesions.


Asunto(s)
Cardias , Estudios de Factibilidad , Neoplasias Gástricas , Humanos , Femenino , Masculino , Persona de Mediana Edad , Cardias/patología , Cardias/diagnóstico por imagen , Adulto , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patología , Anciano , Pólipos/diagnóstico por imagen , Pólipos/diagnóstico , Gastroscopía/métodos , Sensibilidad y Especificidad , Valor Predictivo de las Pruebas , Rayos Láser
3.
Med Eng Phys ; 127: 104170, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692767

RESUMEN

Recently, functional Near-Infrared Spectroscopy (fNIRS) was applied to obtain, non-invasively, the human peri­spinal Neuro-Vascular Response (NVR) under a non-noxious electrical stimulation of a peripheral nerve. This method allowed the measurements of changes in the concentration of oxyhemoglobin (O2Hb) and deoxyhemoglobin (HHb) from the peri­spinal vascular network. However, there is a lack of clarity about the potential differences in perispinal NVR recorded by the different fNIRS technologies currently available. In this work, the two main noninvasive fNIRS technologies were compared, i.e., LED and LASER-based. The recording of the human peri­spinal NVR induced by non-noxious electrical stimulation of a peripheral nerve was recorded simultaneously at C7 and T10 vertebral levels. The amplitude, rise time, and full width at half maximum duration of the perispinal NVRs were characterized in healthy volunteers and compared between both systems. The main difference was that the LED-based system shows about one order of magnitude higher values of amplitude than the LASER-based system. No statistical differences were found for rise time and for duration parameters (at thoracic level). The comparison of point-to-point wave patterns did not show significant differences between both systems. In conclusion, the peri­spinal NRV response obtained by different fNIRS technologies was reproducible, and only the amplitude showed differences, probably due to the power of the system which should be considered when assessing the human peri­spinal vascular network.


Asunto(s)
Rayos Láser , Espectroscopía Infrarroja Corta , Médula Espinal , Humanos , Espectroscopía Infrarroja Corta/métodos , Masculino , Médula Espinal/irrigación sanguínea , Médula Espinal/diagnóstico por imagen , Médula Espinal/fisiología , Adulto , Femenino , Adulto Joven , Estimulación Eléctrica , Hemoglobinas/análisis , Hemoglobinas/metabolismo
4.
Anal Chim Acta ; 1306: 342617, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692789

RESUMEN

BACKGROUND: Alpha-fetoprotein (AFP) is a fetal protein that can indicate congenital anomalies such as Down syndrome and spinal canal blockage when detected at abnormal levels in pregnant women. Current AFP detection methods rely on invasive blood or serum samples, which require sophisticated equipment. From the many solutions proposed, colorimetric paper-based assays excel in point-of-care settings. The concept of paper-based ELISA (p-ELISA) enhances traditional methods, aligning with the ASSURED criteria for diagnostics in resource-limited regions. Despite success in microfluidic paper-based assay devices, laser printing remains underexplored for p-ELISA. Additionally, modifying the paper surface provides an additional layer of sensitivity enhancement. RESULTS: In this study, we developed a novel laser-printed paper-based ELISA (LP-pELISA) for rapid, sensitive, and noninvasive detection of AFP in saliva samples. The LP-pELISA platform was fabricated by printing hydrophobic barriers on filter paper using a laser printer, followed by depositing hydroxyapatite (HAp) as an immobilization material for the antibodies. The colorimetric detection was achieved using AuNPs functionalized with anti-AFP antibodies and silver nitrate enhancement. The LP-pELISA exhibited a linear response for AFP detection in both buffer and saliva samples over a range of 1.0-800 ng mL-1, with a limit of detection (LOD) reaching 1.0 ng mL-1. The assay also demonstrated good selectivity, repeatability, reproducibility, and stability. The LP-pELISA was further validated by testing spiked human saliva samples, showing its potential for point-of-care diagnosis of congenital disabilities. SIGNIFICANCE: The LP-pELISA is a noninvasive platform showcasing simplicity, cost-effectiveness, and user-friendliness, utilizing laser printing, hydroxyapatite modification, and saliva samples to efficiently detect AFP. Beyond its application for AFP, this method's versatility extends to other biomarkers, positioning it as a catalyst for the evolution of paper-based biosensors. The LP-pELISA holds promise as a transformative tool for point-of-care diagnostics, fostering advancements in healthcare with its innovative technology.


Asunto(s)
Colorimetría , Durapatita , Ensayo de Inmunoadsorción Enzimática , Rayos Láser , Papel , Saliva , alfa-Fetoproteínas , Humanos , Saliva/química , Durapatita/química , alfa-Fetoproteínas/análisis , Impresión , Oro/química , Límite de Detección , Anticuerpos Inmovilizados/inmunología , Anticuerpos Inmovilizados/química
5.
Stomatologiia (Mosk) ; 103(2): 86-90, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38741541

RESUMEN

The paper presents an overview of modern scientific data on the study of the effect of laser radiation on biological tissues of the mouth in the therapeutic treatment of dental diseases. The use of lasers in the treatment of dental caries and its complications, non-carious lesions of hard dental tissues, as well as the use of lasers in the treatment of periodontal diseases and aesthetic restoration of teeth is considered.


Asunto(s)
Terapia por Láser , Humanos , Terapia por Láser/métodos , Caries Dental/terapia , Enfermedades Periodontales/terapia , Terapia por Luz de Baja Intensidad/métodos , Rayos Láser
6.
Sci Adv ; 10(19): eadl1586, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38718128

RESUMEN

Viscoelastic transformation of tissue drives aberrant cellular functions and is an early biomarker of disease pathogenesis. Tissues scale a range of viscoelastic moduli, from biofluids to bone. Moreover, viscoelastic behavior is governed by the frequency at which tissue is probed, yielding distinct viscous and elastic responses modulated over a wide frequency band. Existing tools do not quantify wideband viscoelastic spectra in tissues, leaving a vast knowledge gap. We present wideband laser speckle rheological microscopy (WB-SHEAR) that reveals elastic and viscous response over sub-megahertz frequencies previously not investigated in tissue. WB-SHEAR uses an optical, noncontact approach to quantify wideband viscoelastic spectra in specimens spanning a range of moduli from low-viscosity fibrin to highly elastic bone. Via laser scanning, micromechanical imaging is enabled to access wideband viscoelastic spectra in heterogeneous tumor specimens with high spatial resolution (25 micrometers). The ability to interrogate the viscoelastic landscape of diverse biospecimens could transform our understanding of mechanobiological processes in various diseases.


Asunto(s)
Elasticidad , Reología , Viscosidad , Reología/métodos , Humanos , Animales , Rayos Láser , Microscopía/métodos
7.
Mikrochim Acta ; 191(5): 292, 2024 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-38687361

RESUMEN

Since its introduction in 2014, laser-induced graphene (LIG) from commercial polymers has been gaining interests in both academic and industrial sectors. This can be clearly seen from its mass adoption in various fields ranging from energy storage and sensing platforms to biomedical applications. LIG is a 3-dimensional, nanoporous graphene structure with highly tuneable electrical, physical, and chemical properties. LIG can be easily produced by single-step laser scribing at normal room temperature and pressure using easily accessible commercial level laser machines and materials. With the increasing demand for novel wearable devices for biomedical applications, LIG on flexible substrates can readily serve as a technological platform to be further developed for biomedical applications such as point-of-care (POC) testing and wearable devices for healthcare monitoring system. This review will provide a comprehensive grounding on LIG from its inception and fabrication mechanism to the characterization of its key functional properties. The exploration of biomedicals applications in the form of wearable and point-of-care devices will then be presented. Issue of health risk from accidental exposure to LIG will be covered. Then LIG-based wearable devices will be compared to devices of different materials. Finally, we discuss the implementation of Internet of Medical Things (IoMT) to wearable devices and explore and speculate on its potentials and challenges.


Asunto(s)
Grafito , Rayos Láser , Dispositivos Electrónicos Vestibles , Grafito/química , Humanos
8.
ACS Biomater Sci Eng ; 10(5): 2880-2893, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38630940

RESUMEN

Cobalt-chromium-molybdenum (CoCrMo) alloys are common wear-exposed biomedical alloys and are manufactured in multiple ways, increasingly using additive manufacturing processes such as laser powder bed fusion (LPBF). Here, we investigate the effect of proteins and the manufacturing process (wrought vs LPBF) and building orientation (LPBF-XY and XZ) on the corrosion, metal release, tribocorrosion, and surface oxide composition by means of electrochemical, mechanical, microscopic, diffractive, and spectroscopic methods. The study was conducted at pH 7.3 in 5 g/L NaCl and 5 mM 2-(N-morpholino) ethanesulfonic acid (MES) buffer, which was found to be necessary to avoid metal phosphate and metal-protein aggregate precipitation. The effect of 10 g/L bovine serum albumin (BSA) and 2.5 g/L fibrinogen (Fbn) was studied. BSA and Fbn strongly enhanced the release of Co, Cr, and Mo and slightly enhanced the corrosion (still in the passive domain) for all CoCrMo alloys and most for LPBF-XZ, followed by LPBF-XY and the wrought CoCrMo. BSA and Fbn, most pronounced when combined, significantly decreased the coefficient of friction due to lubrication, the wear track width and severity of the wear mechanism, and the tribocorrosion for all alloys, with no clear effect of the manufacturing type. The wear track area was significantly more oxidized than the area outside of the wear track. In the reference solution without proteins, a strong Mo oxidation in the wear track surface oxide was indicative of a pH decrease and cell separation of the anodic and cathodic areas. This effect was absent in the presence of the proteins.


Asunto(s)
Rayos Láser , Albúmina Sérica Bovina , Corrosión , Albúmina Sérica Bovina/química , Bovinos , Animales , Polvos , Fibrinógeno/química , Ensayo de Materiales , Cobalto/química , Propiedades de Superficie , Cromo/química , Vitalio/química
9.
Lasers Med Sci ; 39(1): 102, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38630348

RESUMEN

Alopecia, also known as hair loss, is a highly prevalent condition affecting millions of men and women in the United States and worldwide, making it one of the most common complaints by patients presenting to a dermatologist. The symptomology on the presentation of alopecia can be highly variable, ranging from diffuse thinning of hair, discrete and localized patches completely absent of hair, or noticing significant shedding when brushing and showering. Although alopecia does not have a direct negative health impact on patients, it is nonetheless a debilitating disease as it can profoundly impact an individual's self-image and psychosocial well-being. There are multiple treatment options available to patients with alopecia, and they are typically tailored to the patient's needs and preferences. The most common of these is the Food and Drug Administration-approved drugs for alopecia, minoxidil, and finasteride. However, both of these are known to be partially efficacious for all patients, so clinicians often use different modalities in conjunction with them, in particular laser-based therapies. This review article will provide a comprehensive assessment of lasers and other light therapies that may be used to manage the two most common types of alopecia: androgenetic alopecia and alopecia areata.


Asunto(s)
Alopecia Areata , Masculino , Humanos , Femenino , Cabello , Rayos Láser , Minoxidil/uso terapéutico
10.
Lasers Med Sci ; 39(1): 107, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38635085

RESUMEN

To investigate the in vivo and in situ effect of different types of lasers in prevention of enamel demineralization in high caries risk cases (around orthodontic brackets, around restoration and in caries susceptible pits and fissures). PubMed was searched using the following keyword sequence; (Laser therapy OR laser irradiation OR laser application) AND (enamel caries prevention OR enamel demineralization OR enamel remineralization OR early enamel caries OR early-enamel caries OR enamel resistance OR enamel decalcification OR white spot lesions WSLs OR incipient lesion OR enamel decay OR enamel Dissolution OR enamel microhardness) AND (clinical trial OR Randomized clinical trial OR In situ study). The latest literature search was ended by "30 January 2023". PubMed was used as a primary data base for study selection. Scopus, EBSCO, and Google scholar are checked in our study after results of systematic search on PubMed. Only duplicates were found. Two meta-analyses were carried out. The first, clinical meta-analysis on incidence of white spot lesions (WSLs) following CO2 laser irradiation of enamel. The second meta-analysis on ex-vivo/in situ effect of CO2 laser on microhardness of enamel. In each meta-analysis three studies were included. Risk of bias was assessed. The search identified eight studies (four ex-vivo and four clinical trials). Regarding the clinical meta-analysis, the overall standardized mean difference was 0.21 [ 95% confidence interval (CI): 0.15-0.30, p < 0.00001]. This indicates that the incidence of new WSLs in patients who received low power CO2 laser treatment was highly significantly lower than placebo groups. The heterogeneity was considerable (I2 = 71%). In the second meta-analysis, the overall standardized mean difference was 49.55 [ 95% confidence interval (CI): 37.74, 61.37, p < 0.00001]. This indicates that microhardness of enamel receiving low power (0.4-5 W) CO2 laser irradiation is highly significantly lower than control untreated enamel. The heterogeneity was substantial (I2 = 48%). Within the limitations of this study, Low level laser therapy concept with CO2 laser seems to be effective in preventing enamel caries.Prospero registration number: CRD42023437379.


Asunto(s)
Caries Dental , Terapia por Luz de Baja Intensidad , Humanos , Dióxido de Carbono , Susceptibilidad a Caries Dentarias , Rayos Láser , Ensayos Clínicos Controlados Aleatorios como Asunto
11.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656634

RESUMEN

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Asunto(s)
Reología , Humanos , Cavidad Pulpar/efectos de la radiación , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Rayos Láser , Irrigantes del Conducto Radicular , Técnicas Fotoacústicas/métodos , Preparación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación
12.
Int J Mol Sci ; 25(8)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38674073

RESUMEN

Prostate cancer (PCA) is the second most common cancer diagnosis in men and the fifth leading cause of death worldwide. The conventional treatments available are beneficial to only a few patients and, in those, some present adverse side effects that eventually affect the quality of life of most patients. Thus, there is an urgent need for effective, less invasive and targeted specific treatments for PCA. Photothermal therapy (PTT) is a minimally invasive therapy that provides a localized effect for tumour cell ablation by activating photothermal agents (PTA) that mediate the conversion of the light beam's energy into heat at the site. As tumours are unable to easily dissipate heat, they become more susceptible to temperature increases. In the PTT field, gold nanoparticles (AuNPs) have been attracting interest as PTA. The aim of this study was to formulate AuNPs capable of remaining retained in the tumour and subsequently generating heat at the tumour site. AuNPs were synthesized and characterized in terms of size, polydispersity index (PdI), zeta potential (ZP), morphology and the surface plasmon resonance (SPR). The safety of AuNPs and their efficacy were assessed using in vitro models. A preliminary in vivo safety assessment of AuNPs with a mean size lower than 200 nm was confirmed. The morphology was spherical-like and the SPR band showed good absorbance at the laser wavelength. Without laser, AuNPs proved to be safe both in vitro (>70% viability) and in vivo. In addition, with laser irradiation, they proved to be relatively effective in PCA cells. Overall, the formulation appears to be promising for use in PTT.


Asunto(s)
Oro , Nanopartículas del Metal , Neoplasias de la Próstata , Oro/química , Nanopartículas del Metal/química , Nanopartículas del Metal/uso terapéutico , Masculino , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/terapia , Humanos , Animales , Terapia Fototérmica/métodos , Línea Celular Tumoral , Ratones , Resonancia por Plasmón de Superficie , Rayos Láser
14.
Anal Chem ; 96(18): 7038-7046, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38575850

RESUMEN

Laser-induced breakdown spectroscopy (LIBS) imaging continues to gain strength as an influential bioanalytical technique, showing intriguing potential in the field of clinical analysis. This is because hyperspectral LIBS imaging allows for rapid, comprehensive elemental analysis, covering elements from major to trace levels consistently year after year. In this study, we estimated the potential of a multivariate spectral data treatment approach based on a so-called convex envelope method to detect exotic elements (whether they are minor or in trace amounts) in biopsy tissues of patients with occupational exposure-related diseases. More precisely, we have developed an approach called Interesting Features Finder (IFF), which initially allowed us to identify unexpected elements without any preconceptions, considering only the set of spectra contained in a LIBS hyperspectral data cube. This task is, in fact, almost impossible with conventional chemometric tools, as it entails identifying a few exotic spectra among several hundred thousand others. Once this detection was performed, a second approach based on correlation was used to locate their distribution in the biopsies. Through this unique data analysis pipeline to processing massive LIBS spectroscopic data, it was possible to detect and locate exotic elements such as tin and rhodium in a patient's tissue section, ultimately leading to a possible reclassification of their lung condition as an occupational disease. This review will thus demonstrate the potential of this new diagnostic tool based on LIBS imaging in addressing the shortcomings of approaches developed thus far. The proposed data processing approach naturally transcends this specific framework and can be leveraged across various domains of analytical chemistry, where the detection of rare events is concealed within extensive data sets.


Asunto(s)
Enfermedades Pulmonares , Humanos , Biopsia , Enfermedades Pulmonares/diagnóstico , Enfermedades Pulmonares/patología , Enfermedades Profesionales/diagnóstico , Enfermedades Profesionales/patología , Rayos Láser , Análisis Espectral/métodos , Pulmón/patología , Pulmón/química , Pulmón/diagnóstico por imagen
15.
J Mater Chem B ; 12(19): 4629-4641, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38666407

RESUMEN

Enlightened by the great success of the drug repurposing strategy in the pharmaceutical industry, in the current study, material repurposing is proposed where the performance of carbonyl iron powder (CIP), a nutritional intervention agent of iron supplement approved by the US FDA for iron deficiency anemia in clinic, was explored in anti-cancer treatment. Besides the abnormal iron metabolic characteristics of tumors, serving as potential targets for CIP-based cancer therapy under the repurposing paradigm, the efficacy of CIP as a catalyst in the Fenton reaction, activator for dihydroartemisinin (DHA), thus increasing the chemo-sensitivity of tumors, as well as a potent agent for NIR-II photothermal therapy (PTT) was fully evaluated in an injectable alginate hydrogel form. The CIP-ALG gel caused a rapid temperature rise in the tumor site under NIR-II laser irradiation, leading to complete ablation in the primary tumor. Further, this photothermal-ablation led to the significant release of ATP, and in the bilateral tumor model, both primary tumor ablation and inhibition of secondary tumor were observed simultaneously under the synergistic tumor treatment of nutritional-photothermal therapy (NT/PTT). Thus, material repurposing was confirmed by our pioneering trial and CIP-ALG-meditated NT/PTT/immunotherapy provides a new choice for safe and efficient tumor therapy.


Asunto(s)
Adenosina Trifosfato , Antineoplásicos , Rayos Infrarrojos , Animales , Adenosina Trifosfato/metabolismo , Adenosina Trifosfato/química , Ratones , Antineoplásicos/farmacología , Antineoplásicos/química , Inmunoterapia , Reposicionamiento de Medicamentos , Humanos , Rayos Láser , Terapia Fototérmica , Ratones Endogámicos BALB C , Proliferación Celular/efectos de los fármacos , Línea Celular Tumoral , Alginatos/química , Femenino , Hidrogeles/química , Hidrogeles/farmacología , Ensayos de Selección de Medicamentos Antitumorales , Tamaño de la Partícula , Artemisininas/química , Artemisininas/farmacología
16.
J Biomed Opt ; 29(4): 046008, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38659998

RESUMEN

Significance: Optical imaging is a non-invasive imaging technology that utilizes near-infrared light, allows for the image reconstruction of optical properties like diffuse and absorption coefficients within the tissue. A recent trend is to use signal processing techniques or new light sources and expanding its application. Aim: We aim to develop the reflective optical imaging using the chaotic correlation technology with chaotic laser and optimize the quality and spatial resolution of reflective optical imaging. Approach: Scattering medium was measured using reflective configuration in different inhomogeneous regions to evaluate the performance of the imaging system. The accuracy of the recovered optical properties was investigated. The reconstruction errors of absorption coefficients and geometric centers were analyzed, and the feature metrics of the reconstructed images were evaluated. Results: We showed how chaotic correlation technology can be utilized for information extraction and image reconstruction. This means that a higher signal-to-noise ratio and image reconstruction of inhomogeneous phantoms under different scenarios successfully were achieved. Conclusions: This work highlights that the peak values of correlation of chaotic exhibit smaller reconstruction error and better reconstruction performance in optical imaging compared with reflective optical imaging with the continuous wave laser.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Rayos Láser , Imagen Óptica , Fantasmas de Imagen , Dispersión de Radiación , Imagen Óptica/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Dinámicas no Lineales , Algoritmos , Diseño de Equipo
17.
J Biomed Opt ; 29(Suppl 1): S11530, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38632983

RESUMEN

Significance: In the photoacoustic (PA) technique, the laser irradiation in the time domain (i.e., laser pulse duration) governs the characteristics of PA imaging-it plays a crucial role in the optical-acoustic interaction, the generation of PA signals, and the PA imaging performance. Aim: We aim to provide a comprehensive analysis of the impact of laser pulse duration on various aspects of PA imaging, encompassing the signal-to-noise ratio, the spatial resolution of PA imaging, the acoustic frequency spectrum of the acoustic wave, the initiation of specific physical phenomena, and the photothermal-PA (PT-PA) interaction/conversion. Approach: By surveying and reviewing the state-of-the-art investigations, we discuss the effects of laser pulse duration on the generation of PA signals in the context of biomedical PA imaging with respect to the aforementioned aspects. Results: First, we discuss the impact of laser pulse duration on the PA signal amplitude and its correlation with the lateral resolution of PA imaging. Subsequently, the relationship between the axial resolution of PA imaging and the laser pulse duration is analyzed with consideration of the acoustic frequency spectrum. Furthermore, we examine the manipulation of the pulse duration to trigger physical phenomena and its relevant applications. In addition, we elaborate on the tuning of the pulse duration to manipulate the conversion process and ratio from the PT to PA effect. Conclusions: We contribute to the understanding of the physical mechanisms governing pulse-width-dependent PA techniques. By gaining insight into the mechanism behind the influence of the laser pulse, we can trigger the pulse-with-dependent physical phenomena for specific PA applications, enhance PA imaging performance in biomedical imaging scenarios, and modulate PT-PA conversion by tuning the pulse duration precisely.


Asunto(s)
Luz , Técnicas Fotoacústicas , Análisis Espectral , Relación Señal-Ruido , Acústica , Rayos Láser , Técnicas Fotoacústicas/métodos
18.
Skin Res Technol ; 30(4): e13697, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38634118

RESUMEN

BACKGROUND: One of the common esthetic complaints of patients is horizontal neck wrinkles that have limited treatment modality. AIM: In the present study, we evaluated the efficacy of the Endolift laser on the horizontal neck wrinkles. METHODS: Totally, 10 healthy female and male patients suffering horizontal neck wrinkles were joined in this study. All patients are treated with Endolift laser. The effect of the Endolift methods on the horizontal neck wrinkles was evaluated by biometric parameter changed results with Cutometer, Visioface, and the Skin Ultrasound Imaging system. Also, three blinded dermatologists and patients' satisfaction were evaluated. RESULTS: The Visoface results showed that the Endolift laser treatment significantly decline the depth and area of horizontal neck wrinkle. The skin ultrasonography results reported the epidermis and dermis density and thickness were significantly increased. Also, the cutometer outcomes displayed that the Endolift laser treatment can increase skin elasticity. Also, significantly a greater number of patients were well satisfied with the technique. CONCLUSION: In conclusion, Endolift laser is a safe and effective method for decreasing the horizontal neck wrinkles and improving the appearance of the neck. This procedure does not require general anesthesia and recovery time.


Asunto(s)
Envejecimiento de la Piel , Humanos , Masculino , Femenino , Resultado del Tratamiento , Satisfacción del Paciente , Rayos Láser , Biometría
19.
BMC Pregnancy Childbirth ; 24(1): 300, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649878

RESUMEN

BACKGROUND: Laser-assisted hatching (LAH) stands as the predominant technique for removing the zona pellucida (ZP) in embryos, primarily consisting of two methods: drilling laser-assisted hatching (D-LAH) and thinning laser-assisted hatching (T-LAH). Presently, both methods have limitations, and their comparative efficacy for embryo implantation and clinical pregnancy remains uncertain. AIM: Evaluate the impact of D-LAH and T-LAH on clinical pregnancy rates within assisted reproductive technology (ART). METHODS: We systematically searched electronic databases including PubMed, Web of Science, and Cochrane Library until July 20, 2022. This study encompassed observational studies and randomized controlled trials (RCTs). A 95% confidence interval (CI) was utilized for assessing the risk ratio (RR) of pregnancy outcomes. The level of heterogeneity was measured using I2 statistics, considering a value exceeding 50% as indicative of substantial heterogeneity. RESULTS: The meta-analysis scrutinized 9 studies involving 2405 clinical pregnancies from D-LAH and 2239 from T-LAH. Findings suggested no considerable variation in the clinical pregnancy rates between the two techniques (RR = 0.93, 95% CI: 0.79-1.10, I2 = 71%, P = 0.41). Subgroup analyses also revealed no substantial differences. However, D-LAH exhibited a notably higher occurrence of singleton pregnancies compared to T-LAH (RR = 2.28, 95% CI: 1.08-4.82, I2 = 89%, P = 0.03). There were no noteworthy distinctions observed in other secondary outcomes encompassing implantation rate, multiple pregnancies, ongoing pregnancy, miscarriage, premature birth, and live birth. CONCLUSION: Both the primary findings and subgroup analyses showed no marked variance in clinical pregnancy rates between D-LAH and T-LAH. Therefore, patients with varying conditions should select their preferred LAH technique after assessing their individual situation. However, due to the restricted number of studies involved, accurately gauging the influence of these laser techniques on clinical outcomes is challenging, necessitating further RCTs and high-quality studies to enhance the success rate of ART. TRIAL REGISTRATION: PROSPERO: CRD42022347066.


Asunto(s)
Índice de Embarazo , Técnicas Reproductivas Asistidas , Zona Pelúcida , Humanos , Embarazo , Femenino , Rayos Láser , Implantación del Embrión , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Embarazo , Transferencia de Embrión/métodos
20.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38569484

RESUMEN

A significant modification in photoinduced energy transfer in cancer cells is reported by the assistance of a dynamic modulation of the beam size of laser irradiation. Human lung epithelial cancer cells in monolayer form were studied. In contrast to the quantum and thermal ablation effect promoted by a standard focused Gaussian beam, a spatially modulated beam can caused around 15% of decrease in the ablation threshold and formation of a ring-shaped distribution of the photothermal transfer effect. Optical irradiation was conducted in A549 cells by a 532 nm single-beam emerging from a Nd:YVO4 system. Ablation effects derived from spatially modulated convergent waves were controlled by an electrically focus-tunable lens. The proposed chaotic behavior of the spatial modulation followed an Arneodo chaotic oscillator. Fractional dynamic thermal transport was analyzed in order to describe photoenergy in propagation through the samples. Immediate applications of chaos theory for developing phototechnology devices driving biological functions or phototherapy treatments can be considered.


Asunto(s)
Neoplasias Pulmonares , Dinámicas no Lineales , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología , Células A549 , Rayos Láser , Células Epiteliales/efectos de la radiación , Células Epiteliales/metabolismo , Terapia por Láser/métodos , Línea Celular Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA